_________________

RAMCO®
Manufacturing Company, Inc.
365 Carnegie Avenue
Kenilworth, NJ 07033
Phone: 908.245.4500
Fax: 908.245.3142
E-mail:
info@ramco-safetyshields.com

 
 
Acid Detecting Paints - Solvent

Specifications

ON GUARD™ Acid Detecting Paint is a durable, industrial coating with a unique acid-sensitive component,  which changes color (golden yellow to brilliant red) when exposed to acid or acid vapors  pH 3 or lower.  ON GUARD™ provides an immediate visual indication of a spill or leak, often at quantities that are too small to trigger an exposure with conventional detection devices.  This is a lead-free, all-organic, acrylic modified, alkyd enamel.  Use on potentially hazardous surfaces such as valves, pipes, pumps, flanges, tanks, sample ports, flow indicators, expansion joints, weld sites, clamps, hose connections, truck tanker or tanker car domes, threaded connections, or any place where an accidental leak or spill may occur.  The reaction of ON GUARD™ to acids pH 3 or lower is instantaneous.

PHYSICAL CHARACTERISTICS:

CURING TIME: @ 77 °F (25 °C.):
Appearance Yellow To Touch 30 Min
Solids/Volume 58± 1 % To Handle 1-2 Hours
Viscosity 95-100 KU To Recoat 12-24 Hours
Hide Very Good    
V.O.C. 3.43 lbs/gallon    

TYPICAL USE:  Use ON GUARD™ over primer as a top coat.  The use of ON GUARD™ White Primer #315 is strongly recommended.  This product may cause lifting of inferior sub coats.  Surfaces must be clean, dry, rust, dust, oil, and contamination free.  ON GUARD™ may be used over existing paint if the user is assured that the sub coating is stable and the surface is clean, dry, rust, dust, oil, and contamination free.

THINNING:  ON GUARD™ can be reduced with Xylene solution, if desired.  For air spray, thin up to 10%.  For airless sprayer, brush or roller, thin up to 5%.


STORAGE TEMPERATURE:
  Minimum 20 °F (-7 °C)/Maximum 110 °F (43 °C).
SHELF LIFE:
  Two years in the factory-sealed can at the above storage temperature.
MIXING:
  Stir ON GUARD™ thoroughly, making sure that no pigment remains on the bottom of the can.
COVERAGE RATE:
  250 to 300 square feet per gallon.  Allow for overspray and surface irregularities. 
APPLICATION PROCEDURE:
  Apply ON GUARD™ to achieve 4 mil dry thickness (2-3 brush coats).
SURFACE TEMPERATURE:
 Minimum 40 °F (4 °C) / Maximum 120 °F (49 °C)
CLEAN UP INSTRUCTIONS:
  Clean all equipment immediately after use with Xylene.  Flush and clean spray equipment before material dries.
APPLICATION EQUIPMENT:
  Air or airless spray, brush or roller.

AIR SPRAY:
  Suggested equipment, or equivalent 

Gun Fluid Tip Air Capacity Air Hose ID Material Hose ID Atomizing Pressure Pot Pressure
DeVilbiss, MBC, or JGA E 76.5 or 78 5/15" or 3/8" 3/8" or 1/2" 60-80 psi 10-20 psi

Note:  Low temperature or longer hoses require higher pot pressure


AIRLESS SPRAY:

Tip Orifice

Atomizing Pressure
Material Hose IC

Manifold Filter
0.015"- 0.019"

1800-3000 psi

¼" or 3/8"

60 mesh

Note:  Use appropriate tip and atomizing pressure for equipment, applicator technique and weather conditions.


Home | About Us | Why Safety Shields | Types of Safety Shields | Spra-Gard Safety Shields | Econo-Gard Safety Shields | Metal Safety Shields | Valve-Gard Safety Shields | Specialized RAMCO Safety Shields | Threaded Fittings | Marine Applications | Installation | Selection Guide | Sitemap | Contact Us